Ultrasound-guided Thrombin Injection for the Treatment of Iatrogenic Pseudoaneurysm of the Right Brachial Artery

Main Article Content

Sadisu Mohammed Maaji
Madhan Kumar
Sanjeev Kumar
Dr. Gurpreet Singh Gulati

Abstract

Iatrogenic vascular injury is an abnormal state that occurs in patients as a result of inadvertent or erroneous treatment by physicians or surgeons. Pseudoaneurysms need to be distinguished from true aneurysms. Pseudoaneurysm is a dilatation of an artery with actual
disruption of one or more layers of its wall, rather than with expansion of wall layers. Recently, several reports have suggested that
ultrasound-guided thrombin injection is a safe, effective, and rapid therapy for the treatment of pseudoaneurysm and without being
associated with the limitations of ultrasound-guided manual compression.We report a case of a 38-year-old patient who had brachial
artery pseudoaneurysm and was successfully managed with ultrasound-guided thrombin injection.

Downloads

Download data is not yet available.

Article Details

Section

Case Report

How to Cite

Maaji, S. M., Kumar, M., Kumar, S., & Gulati, D. G. S. (2025). Ultrasound-guided Thrombin Injection for the Treatment of Iatrogenic Pseudoaneurysm of the Right Brachial Artery. West African Journal of Radiology, 24(1), 71-75. https://doi.org/10.82235/wajr.vol24no1.355

References

1. Al Zahrani HA, Saleh TR. Iatrogenic vascular injuries in Western Saudi Arabia. Cardiovasc Surg 1995;3:39‑41.

2. The American Heritage – Steadman’s Medical Dictionary. New York: Houghton Mifflin; 2007. Pseudoaneurysm. Available from: http://www.houghtonmifflinbooks.com/epub/medical.shtml. [Last accessed on 2014 Dec 15].

3. Cina G, De Rosa MG, Viola G, Tazza L. Arterial injuries following diagnostic, therapeutic, and accidental arterial cannulation in haemodialysis patients. Nephrol Dial Transplant 1997;12:1448‑52.

4. Cronenwett JL, Krupski WC. Overview‑arterial aneurysms. In: Rutherford RB, editor. Vascular Surgery. 5th ed., Vol. 2. Philadelphia: WB Saunders; 2000. p. 1241‑5.

5. Brophy DP, Sheiman RG, Amatulle P, Akbari CM. Iatrogenic femoral pseudoaneurysms: Thrombin injection after failed US‑guided compression. Radiology 2000;214:278‑82.

6. Liau CS, Ho FM, Chen MF, Lee YT. Treatment of iatrogenic femoral artery pseudoaneurysm with percutaneous thrombin injection. J Vasc Surg 1997;26:18‑23.

7. Kang SS, Labropoulos N, Mansour MA, Baker WH. Percutaneous ultrasound guided thrombin injection: A new method for treating

postcatheterization femoral pseudoaneurysms. J Vasc Surg 1998;27:1032‑8.

8. Taylor BS, Rhee RY, Muluk S, Trachtenberg J, Walters D, Steed DL, et al. Thrombin injection versus compression of femoral artery pseudoaneurysms. J Vasc Surg 1999;30:1052‑9.

9. Kang SS, Labropoulos N, Mansour MA, Michelini M, Filliung D, Baubly MP, et al. Expanded indications for ultrasound‑guided thrombin injection of pseudoaneurysms. J Vasc Surg 2000;31:289‑98.

10. Johnston KW, Rutherford RB, Tilson MD, Shah DM, Hollier L, Stanley JC. Suggested standards for reporting on arterial aneurysms. Subcommittee on Reporting Standards for Arterial Aneurysms, Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery and North American Chapter, International Society for Cardiovascular Surgery. J Vasc Surg 1991;13:452‑8.

11. Hiatt JR, Hiatt N. Bloodletting in ancient and modern times. Contemp Surg 1996;48:164‑8.

12. Levis JT, Garmel GM. Radial artery pseudoaneurysm formation after cat bite to the wrist. Ann Emerg Med 2008;51:668‑70.

13. Cox GS, Young JR, Gray BR, Grubb MW, Hertzer NR. Ultrasound‑guided compression repair of postcatheterization pseudoaneurysms: Results of treatment in one hundred cases. J Vasc Surg 1994;19:683‑6.

14. McMillan I, Murie JA. Vascular injury following cardiac catheterization. Br J Surg 1984;71:832‑5.

15. Babu SC, Piccorelli GO, Shah PM, Stein JH, Clauss RH. Incidence and results of arterial complications among 16,350 patients undergoing cardiac catheterization. J Vasc Surg 1989;10:113‑6.

16. Wyman RM, Safian RD, Portway V, Skillman JJ, McKay RG, Baim DS. Current complications of diagnostic and therapeutic cardiac catheterization. J Am Coll Cardiol 1988;12:1400‑6.

17. Rapoport S, Sniderman KW, Morse SS, Proto MH, Ross GR. Pseudoaneurysm: A complication of faulty technique in femoral arterial puncture. Radiology 1985;154:529‑30.

18. Adams DF, Fraser DB, Abrams HL. The complications of coronary arteriography. Circulation 1973;48:609‑18.

19. Brener BJ, Couch NP. Peripheral arterial complications of left heart catheterization and their management. Am J Surg 1973;125:521‑6.

20. Bourassa MG, Noble J. Complication rate of coronary arteriography. A review of 5250 cases studied by a percutaneous femoral technique. Circulation 1976;53:106‑14.

21. Kresowik TF, Khoury MD, Miller BV, Winniford MD, Shamma AR, Sharp WJ, et al. A prospective study of the incidence and natural history of femoral vascular complications after percutaneous transluminal coronary angioplasty. J Vasc Surg 1991;13:328‑36.

22. Chatterjee T, Do DD, Kaufmann U, Mahler F, Meier B. Ultrasound‑guided compression repair for treatment of femoral artery pseudoaneurysm: Acute and follow‑up results. Cathet Cardiovasc Diagn 1996;38:335‑40.

23. Poonai N, Lim R, Lynch T. Pseudoaneurysm formation following a traumatic wrist laceration. CJEM 2011;13:48‑52.

24. Khan UD, Page RE. Traumatic aneurysm of the digital artery: A diagnostic problem. Injury 1998;29:727‑9.

25. Hughes CD, Binette C, Babigian A. Pseudoaneurysm in the hand of a three‑year‑old boy: A case report. J Emerg Med 2012;42:e87‑9.

26. Green DP. True and false traumatic aneurysms in the hand. J Bone Joint Surg Am 1973;55:120‑8.

27. Ganchi PA, Wilhelmi BJ, Fujita K, Lee WP. Ruptured pseudoaneurysm complicating an infected radial artery catheter: Case report and review of the literature. Ann Plast Surg 2001;46:647‑50.

28. Gimenez DC, Gilabert OV, Ruiz JG, Muns CY, Alter JB, Cubells MD. Ultrasound and magnetic resonance angiography features of post‑traumatic ulnar artery pseudoaneurysm: A case report and review of the literature. Skeletal Radiol 2009;38:929‑32.

29. Sakamoto A, Arai K. False aneurysm of the superficial palmar arch in a child: A case report. Cases J 2009;2:7985.

30. Brunelli G, Vigasio A, Battiston B, Guizzi P, Brunelli F. Traumatic aneurysms of two proper digital arteries in the same patient: A case report. J Hand Surg Br 1988;13:345‑7.

31. Arriagada Irarrazaval C, Sonneborn Gross R, Sauré Maritano A, Soto Diez C. Posttraumatic pedal artery pseudoaneurysm: A case report. Case Rep Vasc Med 2012;2012:234351.

32. Cope C, Zeit R. Coagulation of aneurysms by direct percutaneous thrombin injection. AJR Am J Roentgenol 1986;147:383‑7.

33. Coley BD, Roberts AC, Fellmeth BD, Valji K, Bookstein JJ, Hye RJ. Postangiographic femoral artery pseudoaneurysms: Further experience with US‑guided compression repair. Radiology 1995;194:307‑11.

34. Middleton WD, Dasyam A, Teefey SA. Diagnosis and treatment of iatrogenic femoral artery pseudoaneurysms. Ultrasound Q 2005;21:3‑17.

35. Reeder SB, Widlus DM, Lazinger M. Low‑dose thrombin injection to treat iatrogenic femoral artery pseudoaneurysms. AJR Am J

Roentgenol 2001;177:595‑8.

36. Lenartova M, Tak T. Iatrogenic pseudoaneurysm of femoral artery: Case report and literature review. Clin Med Res 2003;1:243‑7.

37. Krüger K, Zähringer M, Söhngen FD, Gossmann A, Schulte O, Feldmann C, et al. Femoral pseudoaneurysms: Management with percutaneous thrombin injections – Success rates and effects on systemic coagulation. Radiology 2003;226:452‑8.

Similar Articles

You may also start an advanced similarity search for this article.